Power input |
Input voltage |
380-460V (-15% ~ + 10%), three-phase power |
Input Frequency |
45-65Hz |
|
Allowable voltage fluctuation |
Voltage unbalance <3% |
|
Instant-drop |
Three-phase AC380-460VWhen the power supply input voltage <AC300V when, after 15ms undervoltage protection |
|
Power output |
Voltage |
Input voltage 0VAC ~ |
Overload Class |
Stable 40 ºC, heavy duty 150%, 1min |
|
Efficiency (full load) |
≥0.94 |
|
Output frequency accuracy |
± 0.01% (digital command -10 ~ + 45 ºC) ; ± 0.1% (simulation instruction 25 ± 10 ºC) |
|
Digital I / O |
Opto-isolated input |
7road, 24V high active low can be set, input function can be defined |
Open collector |
2road,Output functions can be defined |
|
Relay output |
2-way, normally open contacts, contact capacity: inductive, 1.5A / 250VAC, output function defined |
|
Analog I / O |
Analog Input Voltage |
2-way,Accuracy 0.1%; Voltage:-10V~ + 10VDCOr Current: 0-20mA optional signal |
Analog voltage output |
2-way,Accuracy 0.1%; Voltage:-10V~ + 10VDCOr Current: 0-20mA optional signal |
|
Control characteristics |
Carrier frequency |
1.1-8 kHz; load characteristics, the carrier frequency can be automatically adjusted |
Frequency setting resolution |
0.01Hz (digital command),± 0.06Hz / 120Hz (11bit + unsigned analog instruction) |
|
Run command channel |
Given the operation panel, a given control terminal, a given communication |
|
Given channel frequency |
Given the operation panel, the digital / analog given, a given communication, performance function given |
|
Torque boost |
Automatic torque boost; Manual torque boost |
|
V / F curve |
Custom V / F Curve linear V / F And three curves of torque-derating |
|
Automatic voltage regulation (AVR) |
Automatically adjusts the output according to the fluctuation of the bus voltage PWM Duty cycle signal, thereby reducing the influence of voltage fluctuations of the output voltage ripple |
|
Instantaneous stop non-stop processing |
When the instantaneous power by bus voltage control, to achieve uninterrupted operation |
|
DC braking capacity |
Braking current:0.0~120.0% Of rated current |
|
Special feature |
Parameter copy |
Standard operating panel can achieve parameter upload, download, copy-progress indicator |
Process PID |
It can be used for closed-loop control of the process variable |
|
Common DC bus |
Full range enabling more than one common DC bus power converter |
|
Motor protection |
Locked rotor |
|
Motor overload |
||
Speed limit |
||
Drive protection |
Output current limit |
|
Inverter overload |
||
IGBT I²t overload |
||
Input Supply Undervoltage / Overvoltage |
||
DC bus under-voltage / overvoltage |
||
IGBT overheating |
||
Radiator overheating |
||
electricity failure |