Customization: | Available |
---|---|
After-sales Service: | with |
Warranty: | 6 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
· High starting torque and load capacity
· Support both synchronous and asynchronous motors
· Perfect, safe and reliable holding brake logic
· Fast, super and highly adaptive dynamic response
· Smooth and impact free speed tracking start
· Supporting PROFIBUS DP and Modbus Communication
· Perfect, safe and reliable protection function of motor drive
· Master-slave control function
· Weak magnetic constant power function
· Torque memory function
· With two sets of motor parameters and operating curve switching function
· Speed / torque static / dynamic switching function
· Non-stop function
Power input |
Input voltage |
380V~460V(-15%~+10%), Three phase power supply, voltage imbalance < 3% |
||
Input frequency |
45~65Hz |
|||
Instantaneous electric drop |
Input: AC 380V~460V, under voltage protection work after 15ms when the input voltage is less than AC300v |
|||
Power output |
Voltage |
AC, 0V-input voltage |
||
Output frequency |
V/F Control: 0.00~300.00Hz, Vector control: 0.00~120.00Hz |
|||
Overload grade |
Heavy load: 150%, 60S; Overload: 200%, 2S |
|||
Output frequency accuracy |
±0.01% (Digital instruction-10~+45ºC) |
|||
Digital I / O |
Optocoupler isolation input |
7 channels, 24V high and low level can be set effectively, and input function can be defined |
||
Open collector output |
2 channels, output function can be defined |
|||
Relay output |
2-channels, normally open, normally closed contact |
|||
Analog I / O |
Analog input |
2 channels, voltage: - 10V ~ + 10VDC or current: 0 ~ 20mA optional signal |
||
Analog output |
2channels, voltage: - 10V ~ + 10VDC or current: 0 ~ 20mA optional signal |
|||
Encoder input |
PG power |
5V, 12V, 300mA |
||
PG signal |
Set open, push-pull, differential, SIN / COS incremental, Endat absolute, resolver, orthogonal set open output, frequency division coefficient 2 / 4 / 8 / 16 / 32 / 64 / 128 can be set (optional) |
|||
Control characteristics |
Control mode |
V/F Control |
Open loop vector control |
Closed loop vector |
Starting torque |
2.50Hz,150% |
0.5Hz,200% |
0.00Hz,200% |
|
Steady speed accuracy |
± 2% |
± 0.2% |
± 0.02% |
|
Torque accuracy |
±5%(closed loop control) |
|||
Torque rise |
Automatic torque rise, manual torque rise |
|||
V/F curve |
User defined V / F curve, linear V / F curve and three kinds of torque reduction characteristic curve |
|||
Automatic voltage regulation |
The duty cycle of output PWM signal is adjusted automatically according to the fluctuation of bus voltage |
|||
Instant stop processing |
In case of instantaneous power failure, uninterrupted operation can be realized by bus voltage control |
|||
Energy consumption braking capacity |
≤22KW, built-in braking unit, external braking resistance (optional) |
|||
DC braking capacity |
Braking current: 0-120.0% of rated current |
|||
Process PID |
Closed loop control of process variables |
|||
Torque control function |
Torque / speed control can be switched through terminals, with multiple torque setting modes |
|||
Zero servo and position control function |
It can realize zero speed position locking, precise positioning and position control |
|||
Common DC bus |
The whole series can realize the common DC bus power supply of multiple drive |
|||
Environment condition |
Place of use |
It is installed in an environment free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam and water dripping |
||
Ambient temperature |
-10~+40ºC |
|||
Altitude |
<1000m |
|||
Ambient humidity |
5~95%,No condensation allowed |
|||
Vibration (installation) |
2≤f<9,0.3mm |
|||
Protection level |
IP00, IP20 |
|||
Other |
Cooling mode |
Forced air cooling |